{"items":[{"id":652,"countryCode":"US","unitName":"ANO-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"B&W LLP (DRYAMB)","alternateName":"Arkansas Nuclear One, Unit 1","typeCode":"PWR","statusCode":"1O","siteId":309,"siteName":"ARKANSAS ONE","thermalPower":2568,"grossElectricalCapacity":903,"netElectricalCapacity":836,"designNetElectricalCapacity":850,"constructionDate":"1968-10-01T00:00:00","criticalityDate":"1974-08-06T00:00:00","gridDate":"1974-08-17T00:00:00","commercialDate":"1974-12-19T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"ENTERGY ARKANSAS, INC.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":808,"defaultImageName":"808.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":457049,"ageNet":457032.00,"lifetimeFactor":null},{"id":689,"countryCode":"US","unitName":"ANO-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE 2LP (DRYAMB)","alternateName":"Arkansas Nuclear One, Unit 2","typeCode":"PWR","statusCode":"1O","siteId":309,"siteName":"ARKANSAS ONE","thermalPower":3026,"grossElectricalCapacity":1065,"netElectricalCapacity":988,"designNetElectricalCapacity":912,"constructionDate":"1968-12-06T00:00:00","criticalityDate":"1978-12-05T00:00:00","gridDate":"1978-12-26T00:00:00","commercialDate":"1980-03-26T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"ENTERGY ARKANSAS, INC.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":808,"defaultImageName":"808.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":418841,"ageNet":418824.00,"lifetimeFactor":null},{"id":669,"countryCode":"US","unitName":"BEAVER VALLEY-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYSUB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":313,"siteName":"BEAVER VALLEY","thermalPower":2900,"grossElectricalCapacity":959,"netElectricalCapacity":908,"designNetElectricalCapacity":835,"constructionDate":"1970-06-26T00:00:00","criticalityDate":"1976-05-10T00:00:00","gridDate":"1976-06-14T00:00:00","commercialDate":"1976-10-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"FIRST ENERGY NUCLEAR OPERATING CO.","ownerName":"PPL Susquehanna, LLC","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":86,"defaultImageName":"86.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":441041,"ageNet":441024.00,"lifetimeFactor":null},{"id":712,"countryCode":"US","unitName":"BEAVER VALLEY-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYSUB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":313,"siteName":"BEAVER VALLEY","thermalPower":2900,"grossElectricalCapacity":958,"netElectricalCapacity":905,"designNetElectricalCapacity":836,"constructionDate":"1974-05-03T00:00:00","criticalityDate":"1987-08-04T00:00:00","gridDate":"1987-08-17T00:00:00","commercialDate":"1987-11-17T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"FIRST ENERGY NUCLEAR OPERATING CO.","ownerName":"OHIO EDISON CO.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":86,"defaultImageName":"86.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":343097,"ageNet":343080.00,"lifetimeFactor":null},{"id":601,"countryCode":"US","unitName":"BIG ROCK POINT","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"-","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":316,"siteName":"BIG ROCK POINT","thermalPower":240,"grossElectricalCapacity":71,"netElectricalCapacity":67,"designNetElectricalCapacity":72,"constructionDate":"1960-05-01T00:00:00","criticalityDate":"1962-09-27T00:00:00","gridDate":"1962-12-08T00:00:00","commercialDate":"1963-03-29T00:00:00","shutdownDate":"1997-08-29T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"CONSUMERS POWER CO.","ownerName":"CONSUMERS POWER CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":559529,"ageNet":304392.00,"lifetimeFactor":null},{"id":703,"countryCode":"US","unitName":"BONUS","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"Superheater","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":319,"siteName":"BONUS","thermalPower":50,"grossElectricalCapacity":18,"netElectricalCapacity":17,"designNetElectricalCapacity":17,"constructionDate":"1960-01-01T00:00:00","criticalityDate":"1964-04-13T00:00:00","gridDate":"1964-08-14T00:00:00","commercialDate":"1965-09-01T00:00:00","shutdownDate":"1968-06-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"DOE & PUERTO RICO WATER RESOURCES","ownerName":"US DOE and Puerto Rico Electric Power Authority","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GNEPRWRA","reactorSupplierName":"GENERAL NUCLEAR ENGINEERING & PUERTO RICO WATER RESOURCES AUTHORITY (US)","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":544769,"ageNet":33288.00,"lifetimeFactor":null},{"id":737,"countryCode":"US","unitName":"BRAIDWOOD-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":320,"siteName":"BRAIDWOOD","thermalPower":3645,"grossElectricalCapacity":1270,"netElectricalCapacity":1194,"designNetElectricalCapacity":1120,"constructionDate":"1975-08-01T00:00:00","criticalityDate":"1987-05-29T00:00:00","gridDate":"1987-07-12T00:00:00","commercialDate":"1988-07-29T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":340,"defaultImageName":"340.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":343961,"ageNet":343944.00,"lifetimeFactor":null},{"id":738,"countryCode":"US","unitName":"BRAIDWOOD-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":320,"siteName":"BRAIDWOOD","thermalPower":3645,"grossElectricalCapacity":1230,"netElectricalCapacity":1160,"designNetElectricalCapacity":1120,"constructionDate":"1975-08-01T00:00:00","criticalityDate":"1988-03-08T00:00:00","gridDate":"1988-05-25T00:00:00","commercialDate":"1988-10-17T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":340,"defaultImageName":"340.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":336329,"ageNet":336312.00,"lifetimeFactor":null},{"id":617,"countryCode":"US","unitName":"BROWNS FERRY-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":321,"siteName":"BROWNS FERRY","thermalPower":3458,"grossElectricalCapacity":1256,"netElectricalCapacity":1200,"designNetElectricalCapacity":1065,"constructionDate":"1967-05-01T00:00:00","criticalityDate":"1973-08-17T00:00:00","gridDate":"1973-10-15T00:00:00","commercialDate":"1974-12-20T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":"1985-03-19T00:00:00","latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Tennessee Valley Authority","ownerName":"Tennessee Valley Authority","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":118,"defaultImageName":"118.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":"2007-06-02T00:00:00","ageGross":464393,"ageNet":269736.00,"lifetimeFactor":null},{"id":618,"countryCode":"US","unitName":"BROWNS FERRY-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":321,"siteName":"BROWNS FERRY","thermalPower":3458,"grossElectricalCapacity":1259,"netElectricalCapacity":1200,"designNetElectricalCapacity":1065,"constructionDate":"1967-05-01T00:00:00","criticalityDate":"1974-07-20T00:00:00","gridDate":"1974-08-28T00:00:00","commercialDate":"1975-03-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":"1985-03-01T00:00:00","latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Tennessee Valley Authority","ownerName":"Tennessee Valley Authority","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":118,"defaultImageName":"118.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":"1991-05-24T00:00:00","ageGross":456785,"ageNet":402168.00,"lifetimeFactor":null},{"id":641,"countryCode":"US","unitName":"BROWNS FERRY-3","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":321,"siteName":"BROWNS FERRY","thermalPower":3458,"grossElectricalCapacity":1260,"netElectricalCapacity":1210,"designNetElectricalCapacity":1065,"constructionDate":"1968-07-01T00:00:00","criticalityDate":"1976-08-08T00:00:00","gridDate":"1976-09-12T00:00:00","commercialDate":"1977-03-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":"1985-03-01T00:00:00","latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Tennessee Valley Authority","ownerName":"Tennessee Valley Authority","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":118,"defaultImageName":"118.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":"1995-11-01T00:00:00","ageGross":438881,"ageNet":345336.00,"lifetimeFactor":null},{"id":662,"countryCode":"US","unitName":"BRUNSWICK-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":322,"siteName":"BRUNSWICK","thermalPower":2923,"grossElectricalCapacity":990,"netElectricalCapacity":938,"designNetElectricalCapacity":821,"constructionDate":"1970-02-07T00:00:00","criticalityDate":"1976-10-08T00:00:00","gridDate":"1976-12-04T00:00:00","commercialDate":"1977-03-18T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Progress Energy","ownerName":"PROGRESS ENERGY Carolinas, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":53,"defaultImageName":"53.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":436889,"ageNet":436872.00,"lifetimeFactor":null},{"id":661,"countryCode":"US","unitName":"BRUNSWICK-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":322,"siteName":"BRUNSWICK","thermalPower":2923,"grossElectricalCapacity":960,"netElectricalCapacity":932,"designNetElectricalCapacity":821,"constructionDate":"1970-02-07T00:00:00","criticalityDate":"1975-03-20T00:00:00","gridDate":"1975-04-29T00:00:00","commercialDate":"1975-11-03T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Progress Energy","ownerName":"PROGRESS ENERGY Carolinas, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":53,"defaultImageName":"53.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":450929,"ageNet":450912.00,"lifetimeFactor":null},{"id":735,"countryCode":"US","unitName":"BYRON-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":323,"siteName":"BYRON","thermalPower":3645,"grossElectricalCapacity":1242,"netElectricalCapacity":1164,"designNetElectricalCapacity":1120,"constructionDate":"1975-04-01T00:00:00","criticalityDate":"1985-02-02T00:00:00","gridDate":"1985-03-01T00:00:00","commercialDate":"1985-09-16T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":346,"defaultImageName":"346.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":364673,"ageNet":364656.00,"lifetimeFactor":null},{"id":736,"countryCode":"US","unitName":"BYRON-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":323,"siteName":"BYRON","thermalPower":3645,"grossElectricalCapacity":1210,"netElectricalCapacity":1136,"designNetElectricalCapacity":1120,"constructionDate":"1975-04-01T00:00:00","criticalityDate":"1987-01-09T00:00:00","gridDate":"1987-02-06T00:00:00","commercialDate":"1987-08-02T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":346,"defaultImageName":"346.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":347705,"ageNet":347688.00,"lifetimeFactor":null},{"id":752,"countryCode":"US","unitName":"CALLAWAY-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":324,"siteName":"CALLAWAY","thermalPower":3565,"grossElectricalCapacity":1275,"netElectricalCapacity":1215,"designNetElectricalCapacity":1171,"constructionDate":"1975-09-01T00:00:00","criticalityDate":"1984-10-02T00:00:00","gridDate":"1984-10-24T00:00:00","commercialDate":"1984-12-19T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"AMEREN UE, Union Electric Company","ownerName":"AMEREN UE, Union Electric Company","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":367745,"ageNet":367728.00,"lifetimeFactor":null},{"id":655,"countryCode":"US","unitName":"CALVERT CLIFFS-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":325,"siteName":"CALVERT CLIFFS","thermalPower":2737,"grossElectricalCapacity":918,"netElectricalCapacity":877,"designNetElectricalCapacity":845,"constructionDate":"1968-06-01T00:00:00","criticalityDate":"1974-10-07T00:00:00","gridDate":"1975-01-03T00:00:00","commercialDate":"1975-05-08T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":453713,"ageNet":453696.00,"lifetimeFactor":null},{"id":656,"countryCode":"US","unitName":"CALVERT CLIFFS-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":325,"siteName":"CALVERT CLIFFS","thermalPower":2737,"grossElectricalCapacity":911,"netElectricalCapacity":855,"designNetElectricalCapacity":845,"constructionDate":"1968-06-01T00:00:00","criticalityDate":"1976-11-30T00:00:00","gridDate":"1976-12-07T00:00:00","commercialDate":"1977-04-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":436817,"ageNet":436800.00,"lifetimeFactor":null},{"id":713,"countryCode":"US","unitName":"CATAWBA-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECND)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":326,"siteName":"CATAWBA","thermalPower":3411,"grossElectricalCapacity":1188,"netElectricalCapacity":1160,"designNetElectricalCapacity":1145,"constructionDate":"1974-05-01T00:00:00","criticalityDate":"1985-01-07T00:00:00","gridDate":"1985-01-22T00:00:00","commercialDate":"1985-06-29T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Duke Energy  Corp.","ownerName":"North Carolina Electric Membership Corp.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":73,"defaultImageName":"73.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":365585,"ageNet":365568.00,"lifetimeFactor":null},{"id":714,"countryCode":"US","unitName":"CATAWBA-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECND)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":326,"siteName":"CATAWBA","thermalPower":3411,"grossElectricalCapacity":1188,"netElectricalCapacity":1150,"designNetElectricalCapacity":1145,"constructionDate":"1974-05-01T00:00:00","criticalityDate":"1986-05-08T00:00:00","gridDate":"1986-05-18T00:00:00","commercialDate":"1986-08-19T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Duke Energy  Corp.","ownerName":"North Carolina Municipal Power Agency No.1","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":73,"defaultImageName":"73.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":354041,"ageNet":354024.00,"lifetimeFactor":null},{"id":742,"countryCode":"US","unitName":"CLINTON-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-6 (Mark 3)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":330,"siteName":"CLINTON","thermalPower":3473,"grossElectricalCapacity":1098,"netElectricalCapacity":1062,"designNetElectricalCapacity":950,"constructionDate":"1975-10-01T00:00:00","criticalityDate":"1987-02-27T00:00:00","gridDate":"1987-04-24T00:00:00","commercialDate":"1987-11-24T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":352,"defaultImageName":"352.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":345857,"ageNet":345840.00,"lifetimeFactor":null},{"id":702,"countryCode":"US","unitName":"COLUMBIA","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-5 (Mark 2)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":331,"siteName":"COLUMBIA","thermalPower":3486,"grossElectricalCapacity":1190,"netElectricalCapacity":1131,"designNetElectricalCapacity":1100,"constructionDate":"1972-08-01T00:00:00","criticalityDate":"1984-01-19T00:00:00","gridDate":"1984-05-27T00:00:00","commercialDate":"1984-12-13T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Energy Northwest","ownerName":"Energy Northwest","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":814,"defaultImageName":"814.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":371345,"ageNet":371328.00,"lifetimeFactor":null},{"id":729,"countryCode":"US","unitName":"COMANCHE PEAK-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":332,"siteName":"COMANCHE PEAK","thermalPower":3612,"grossElectricalCapacity":1259,"netElectricalCapacity":1205,"designNetElectricalCapacity":1150,"constructionDate":"1974-12-19T00:00:00","criticalityDate":"1990-04-03T00:00:00","gridDate":"1990-04-24T00:00:00","commercialDate":"1990-08-13T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Luminant Generation Company, LLC","ownerName":"Luminant Generation Company, LLC","turbineSupplierCode":"AC","turbineSupplierName":"ALLIS CHALMERS","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":79,"defaultImageName":"79.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":319553,"ageNet":319536.00,"lifetimeFactor":null},{"id":730,"countryCode":"US","unitName":"COMANCHE PEAK-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":332,"siteName":"COMANCHE PEAK","thermalPower":3612,"grossElectricalCapacity":1250,"netElectricalCapacity":1195,"designNetElectricalCapacity":1150,"constructionDate":"1974-12-19T00:00:00","criticalityDate":"1993-03-24T00:00:00","gridDate":"1993-04-09T00:00:00","commercialDate":"1993-08-03T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Luminant Generation Company, LLC","ownerName":"Luminant Generation Company, LLC","turbineSupplierCode":"AC","turbineSupplierName":"ALLIS CHALMERS","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":79,"defaultImageName":"79.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":293609,"ageNet":293592.00,"lifetimeFactor":null},{"id":653,"countryCode":"US","unitName":"COOK-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECDN)","alternateName":"Donald C. Cook 1","typeCode":"PWR","statusCode":"1O","siteId":338,"siteName":"DONALD COOK","thermalPower":3304,"grossElectricalCapacity":1131,"netElectricalCapacity":1030,"designNetElectricalCapacity":1030,"constructionDate":"1969-03-25T00:00:00","criticalityDate":"1975-01-18T00:00:00","gridDate":"1975-02-10T00:00:00","commercialDate":"1975-08-28T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"American Electric Power Company, Inc.","ownerName":"American Electric Power Company, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":59,"defaultImageName":"59.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":452801,"ageNet":452784.00,"lifetimeFactor":null},{"id":654,"countryCode":"US","unitName":"COOK-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECDN)","alternateName":"Donald C. Cook 2","typeCode":"PWR","statusCode":"1O","siteId":338,"siteName":"DONALD COOK","thermalPower":3468,"grossElectricalCapacity":1231,"netElectricalCapacity":1168,"designNetElectricalCapacity":1100,"constructionDate":"1969-03-25T00:00:00","criticalityDate":"1978-03-10T00:00:00","gridDate":"1978-03-22T00:00:00","commercialDate":"1978-07-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"American Electric Power Company, Inc.","ownerName":"American Electric Power Company, Inc.","turbineSupplierCode":"BB&C","turbineSupplierName":"BROWN BOVERI & CIE","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":59,"defaultImageName":"59.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":425537,"ageNet":425520.00,"lifetimeFactor":null},{"id":642,"countryCode":"US","unitName":"COOPER","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":333,"siteName":"COOPER","thermalPower":2419,"grossElectricalCapacity":801,"netElectricalCapacity":769,"designNetElectricalCapacity":778,"constructionDate":"1968-06-01T00:00:00","criticalityDate":"1974-02-21T00:00:00","gridDate":"1974-05-10T00:00:00","commercialDate":"1974-07-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"NEBRASKA PUBLIC POWER DISTRICT","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":532,"defaultImageName":"532.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":459425,"ageNet":459408.00,"lifetimeFactor":null},{"id":645,"countryCode":"US","unitName":"CRYSTAL RIVER-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"B&W LLP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":334,"siteName":"CRYSTAL RIVER","thermalPower":2568,"grossElectricalCapacity":890,"netElectricalCapacity":860,"designNetElectricalCapacity":825,"constructionDate":"1968-09-25T00:00:00","criticalityDate":"1977-01-14T00:00:00","gridDate":"1977-01-30T00:00:00","commercialDate":"1977-03-13T00:00:00","shutdownDate":"2013-02-05T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Progress Energy","ownerName":"Duke Energy  Corp.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":60,"defaultImageName":"60.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":435521,"ageNet":315720.00,"lifetimeFactor":null},{"id":600,"countryCode":"US","unitName":"CVTR","typeName":"Pressurized Heavy-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"Prototype","alternateName":"Carolinas–Virginia Tube Reactor","typeCode":"PHWR","statusCode":"4S","siteId":335,"siteName":"CVTR","thermalPower":65,"grossElectricalCapacity":19,"netElectricalCapacity":17,"designNetElectricalCapacity":17,"constructionDate":"1960-01-01T00:00:00","criticalityDate":"1963-03-01T00:00:00","gridDate":"1963-12-18T00:00:00","commercialDate":"1963-12-18T00:00:00","shutdownDate":"1967-01-10T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"CAROLINAS-VIRGINIA NUCLEAR POWER ASSOC.","ownerName":"CAROLINAS-VIRGINIA NUCLEAR POWER ASSOC.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":550529,"ageNet":26856.00,"lifetimeFactor":null},{"id":676,"countryCode":"US","unitName":"DAVIS BESSE-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"B&W RLP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":336,"siteName":"DAVIS BESSE","thermalPower":2817,"grossElectricalCapacity":925,"netElectricalCapacity":894,"designNetElectricalCapacity":906,"constructionDate":"1970-09-01T00:00:00","criticalityDate":"1977-08-12T00:00:00","gridDate":"1977-08-28T00:00:00","commercialDate":"1978-07-31T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"FIRST ENERGY NUCLEAR OPERATING CO.","ownerName":"CLEVELAND ELECTRIC ILLUMINATING CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":700,"defaultImageName":"700.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":430481,"ageNet":430464.00,"lifetimeFactor":null},{"id":628,"countryCode":"US","unitName":"DIABLO CANYON-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":337,"siteName":"DIABLO CANYON","thermalPower":3411,"grossElectricalCapacity":1197,"netElectricalCapacity":1138,"designNetElectricalCapacity":1084,"constructionDate":"1968-04-23T00:00:00","criticalityDate":"1984-04-29T00:00:00","gridDate":"1984-11-11T00:00:00","commercialDate":"1985-05-07T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Pacific Gas and Electric Company\r\n","ownerName":"PG&E Corporation","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":818,"defaultImageName":"818.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":367313,"ageNet":367296.00,"lifetimeFactor":null},{"id":660,"countryCode":"US","unitName":"DIABLO CANYON-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":337,"siteName":"DIABLO CANYON","thermalPower":3411,"grossElectricalCapacity":1197,"netElectricalCapacity":1118,"designNetElectricalCapacity":1106,"constructionDate":"1970-12-09T00:00:00","criticalityDate":"1985-08-19T00:00:00","gridDate":"1985-10-20T00:00:00","commercialDate":"1986-03-13T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Pacific Gas and Electric Company\r\n","ownerName":"PG&E Corporation","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":818,"defaultImageName":"818.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":359081,"ageNet":359064.00,"lifetimeFactor":null},{"id":597,"countryCode":"US","unitName":"DRESDEN-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":null,"alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":340,"siteName":"DRESDEN","thermalPower":700,"grossElectricalCapacity":207,"netElectricalCapacity":197,"designNetElectricalCapacity":192,"constructionDate":"1956-05-01T00:00:00","criticalityDate":"1959-10-15T00:00:00","gridDate":"1960-04-15T00:00:00","commercialDate":"1960-07-04T00:00:00","shutdownDate":"1978-10-31T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":null,"turbineSupplierCode":null,"turbineSupplierName":null,"reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":353,"defaultImageName":"353.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":582737,"ageNet":162552.00,"lifetimeFactor":null},{"id":608,"countryCode":"US","unitName":"DRESDEN-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-3 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":340,"siteName":"DRESDEN","thermalPower":2957,"grossElectricalCapacity":950,"netElectricalCapacity":894,"designNetElectricalCapacity":794,"constructionDate":"1966-01-10T00:00:00","criticalityDate":"1970-01-07T00:00:00","gridDate":"1970-04-13T00:00:00","commercialDate":"1970-06-09T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":353,"defaultImageName":"353.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":495137,"ageNet":495120.00,"lifetimeFactor":null},{"id":612,"countryCode":"US","unitName":"DRESDEN-3","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-3 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":340,"siteName":"DRESDEN","thermalPower":2957,"grossElectricalCapacity":935,"netElectricalCapacity":879,"designNetElectricalCapacity":794,"constructionDate":"1966-10-14T00:00:00","criticalityDate":"1971-01-12T00:00:00","gridDate":"1971-07-22T00:00:00","commercialDate":"1971-11-16T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":353,"defaultImageName":"353.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":483977,"ageNet":483960.00,"lifetimeFactor":null},{"id":667,"countryCode":"US","unitName":"DUANE ARNOLD-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":341,"siteName":"DUANE ARNOLD","thermalPower":1912,"grossElectricalCapacity":624,"netElectricalCapacity":601,"designNetElectricalCapacity":538,"constructionDate":"1970-06-22T00:00:00","criticalityDate":"1974-03-23T00:00:00","gridDate":"1974-05-19T00:00:00","commercialDate":"1975-02-01T00:00:00","shutdownDate":"2020-10-12T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"NextEra Energy Resources, LLC\r\n","ownerName":"NextEra Energy Resources, LLC\r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":67,"defaultImageName":"67.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":459209,"ageNet":406752.00,"lifetimeFactor":null},{"id":596,"countryCode":"US","unitName":"ELK RIVER","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"-","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":342,"siteName":"ELK RIVER","thermalPower":58,"grossElectricalCapacity":24,"netElectricalCapacity":22,"designNetElectricalCapacity":22,"constructionDate":"1959-01-01T00:00:00","criticalityDate":"1962-11-01T00:00:00","gridDate":"1963-08-24T00:00:00","commercialDate":"1964-07-01T00:00:00","shutdownDate":"1968-02-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"RURAL COOPERATIVE POWER ASSOC.","ownerName":"US Department of Energy","turbineSupplierCode":"AC","turbineSupplierName":"ALLIS CHALMERS","reactorSupplierCode":"AC","reactorSupplierName":"ALLIS CHALMERS","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":553313,"ageNet":38928.00,"lifetimeFactor":null},{"id":677,"countryCode":"US","unitName":"FARLEY-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":345,"siteName":"FARLEY","thermalPower":2775,"grossElectricalCapacity":918,"netElectricalCapacity":874,"designNetElectricalCapacity":829,"constructionDate":"1970-10-01T00:00:00","criticalityDate":"1977-08-09T00:00:00","gridDate":"1977-08-18T00:00:00","commercialDate":"1977-12-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Southern Nuclear Operating Company, Inc.","ownerName":"Alabama Power Company","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":430721,"ageNet":430704.00,"lifetimeFactor":null},{"id":686,"countryCode":"US","unitName":"FARLEY-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":345,"siteName":"FARLEY","thermalPower":2775,"grossElectricalCapacity":928,"netElectricalCapacity":883,"designNetElectricalCapacity":829,"constructionDate":"1970-10-01T00:00:00","criticalityDate":"1981-05-05T00:00:00","gridDate":"1981-05-25T00:00:00","commercialDate":"1981-07-30T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Southern Nuclear Operating Company, Inc.","ownerName":"Alabama Power Company","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":397697,"ageNet":397680.00,"lifetimeFactor":null},{"id":602,"countryCode":"US","unitName":"FERMI-1","typeName":"Fast Breeder Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"Liquid Metal FBR","alternateName":"Enrico Fermi 1","typeCode":"FBR","statusCode":"4S","siteId":343,"siteName":"ENRICO FERMI","thermalPower":200,"grossElectricalCapacity":65,"netElectricalCapacity":60,"designNetElectricalCapacity":60,"constructionDate":"1956-08-08T00:00:00","criticalityDate":"1963-08-23T00:00:00","gridDate":"1966-08-05T00:00:00","commercialDate":"1966-08-07T00:00:00","shutdownDate":"1972-11-29T00:00:00","constructionLicenseDate":"1956-01-15T00:00:00","decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"DETROIT EDISON CO.","ownerName":"Power Reactor Development Company (PRDC), consortium of 34 public utilities","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"UEC","reactorSupplierName":"UNITED ENGINEERS AND CONTRACTORS","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":527465,"ageNet":55392.00,"lifetimeFactor":null},{"id":674,"countryCode":"US","unitName":"FERMI-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":"Enrico Fermi 2","typeCode":"BWR","statusCode":"1O","siteId":343,"siteName":"ENRICO FERMI","thermalPower":3486,"grossElectricalCapacity":1198,"netElectricalCapacity":1115,"designNetElectricalCapacity":1093,"constructionDate":"1972-09-26T00:00:00","criticalityDate":"1985-06-21T00:00:00","gridDate":"1986-09-21T00:00:00","commercialDate":"1988-01-23T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"DETROIT EDISON CO.","ownerName":"DTE Energy Co.","turbineSupplierCode":"GECTG","turbineSupplierName":"GEC TURBINE GENERATORS, LTD.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":351017,"ageNet":351000.00,"lifetimeFactor":null},{"id":668,"countryCode":"US","unitName":"FITZPATRICK","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":346,"siteName":"FITZPATRICK","thermalPower":2536,"grossElectricalCapacity":849,"netElectricalCapacity":813,"designNetElectricalCapacity":821,"constructionDate":"1968-09-01T00:00:00","criticalityDate":"1974-11-17T00:00:00","gridDate":"1975-02-01T00:00:00","commercialDate":"1975-07-28T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":453017,"ageNet":453000.00,"lifetimeFactor":null},{"id":634,"countryCode":"US","unitName":"FORT CALHOUN-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"CE 2LP","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":349,"siteName":"FORT CALHOUN","thermalPower":1500,"grossElectricalCapacity":512,"netElectricalCapacity":482,"designNetElectricalCapacity":478,"constructionDate":"1968-06-07T00:00:00","criticalityDate":"1973-08-06T00:00:00","gridDate":"1973-08-25T00:00:00","commercialDate":"1973-09-26T00:00:00","shutdownDate":"2016-10-24T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"OMAHA PUBLIC POWER DISTRICT","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":821,"defaultImageName":"821.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":465617,"ageNet":378384.00,"lifetimeFactor":null},{"id":623,"countryCode":"US","unitName":"FORT ST. VRAIN","typeName":"High-Temperature Gas-Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":null,"alternateName":null,"typeCode":"HTGR","statusCode":"4S","siteId":350,"siteName":"FORT ST. VRAIN","thermalPower":842,"grossElectricalCapacity":342,"netElectricalCapacity":330,"designNetElectricalCapacity":330,"constructionDate":"1968-09-01T00:00:00","criticalityDate":"1974-01-31T00:00:00","gridDate":"1976-12-11T00:00:00","commercialDate":"1979-07-01T00:00:00","shutdownDate":"1989-08-29T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"PUBLIC SERVICE CO. OF COLORADO","ownerName":null,"turbineSupplierCode":null,"turbineSupplierName":null,"reactorSupplierCode":"GA","reactorSupplierName":"GENERAL ATOMIC CORP.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":436721,"ageNet":111456.00,"lifetimeFactor":null},{"id":893,"countryCode":"US","unitName":"GE VALLECITOS","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"25","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":425,"siteName":"VALLECITOS","thermalPower":50,"grossElectricalCapacity":24,"netElectricalCapacity":24,"designNetElectricalCapacity":24,"constructionDate":"1956-01-01T00:00:00","criticalityDate":"1957-08-03T00:00:00","gridDate":"1957-10-19T00:00:00","commercialDate":"1957-10-19T00:00:00","shutdownDate":"1963-12-09T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"General Electric","ownerName":"General Electric and Pacific Gas and Electric Company","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":604553,"ageNet":53808.00,"lifetimeFactor":null},{"id":609,"countryCode":"US","unitName":"GINNA","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 2LP (DRYAMB)","alternateName":"R. E. Ginna","typeCode":"PWR","statusCode":"1O","siteId":399,"siteName":"R.E. GINNA","thermalPower":1775,"grossElectricalCapacity":608,"netElectricalCapacity":560,"designNetElectricalCapacity":470,"constructionDate":"1966-04-25T00:00:00","criticalityDate":"1969-11-08T00:00:00","gridDate":"1969-12-02T00:00:00","commercialDate":"1970-07-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":498305,"ageNet":498288.00,"lifetimeFactor":null},{"id":715,"countryCode":"US","unitName":"GRAND GULF-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-6 (Mark 3)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":352,"siteName":"GRAND GULF","thermalPower":4408,"grossElectricalCapacity":1500,"netElectricalCapacity":1401,"designNetElectricalCapacity":1250,"constructionDate":"1974-05-04T00:00:00","criticalityDate":"1982-08-18T00:00:00","gridDate":"1984-10-20T00:00:00","commercialDate":"1985-07-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"Systems Energy Resources, Inc","turbineSupplierCode":"KWU","turbineSupplierName":"KRAFTWERK UNION, AG","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":720,"defaultImageName":"720.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":367841,"ageNet":367824.00,"lifetimeFactor":null},{"id":605,"countryCode":"US","unitName":"HADDAM NECK","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"-","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":356,"siteName":"HADDAM NECK","thermalPower":1825,"grossElectricalCapacity":603,"netElectricalCapacity":560,"designNetElectricalCapacity":582,"constructionDate":"1964-05-01T00:00:00","criticalityDate":"1967-07-24T00:00:00","gridDate":"1967-08-07T00:00:00","commercialDate":"1968-01-01T00:00:00","shutdownDate":"1996-12-05T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"CONNECTICUT YANKEE ATOMIC POWER CO.","ownerName":"CONNECTICUT YANKEE ATOMIC POWER CO.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":518657,"ageNet":257112.00,"lifetimeFactor":null},{"id":891,"countryCode":"US","unitName":"HALLAM","typeName":"Sodium Graphite Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"LMGMR (SGR- Sodium cooled graphite moderated reactor)","alternateName":null,"typeCode":"SGR","statusCode":"4S","siteId":376,"siteName":"NEBRASKA","thermalPower":256,"grossElectricalCapacity":84,"netElectricalCapacity":75,"designNetElectricalCapacity":75,"constructionDate":"1959-01-01T00:00:00","criticalityDate":"1963-01-01T00:00:00","gridDate":"1963-09-01T00:00:00","commercialDate":"1963-11-01T00:00:00","shutdownDate":"1964-09-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Atomic Energy Commission and Nebraska Public Power District","ownerName":"HALLAM Nucler Power Facility","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":553121,"ageNet":8784.00,"lifetimeFactor":null},{"id":704,"countryCode":"US","unitName":"HARRIS-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYAMB)","alternateName":"Shearon Harris 1","typeCode":"PWR","statusCode":"1O","siteId":407,"siteName":"SHEARON HARRIS","thermalPower":2900,"grossElectricalCapacity":980,"netElectricalCapacity":964,"designNetElectricalCapacity":900,"constructionDate":"1978-01-28T00:00:00","criticalityDate":"1987-01-03T00:00:00","gridDate":"1987-01-19T00:00:00","commercialDate":"1987-05-02T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Progress Energy","ownerName":"PROGRESS ENERGY Carolinas, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":69,"defaultImageName":"69.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":348137,"ageNet":348120.00,"lifetimeFactor":null},{"id":658,"countryCode":"US","unitName":"HATCH-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":358,"siteName":"HATCH","thermalPower":2804,"grossElectricalCapacity":911,"netElectricalCapacity":876,"designNetElectricalCapacity":777,"constructionDate":"1968-09-30T00:00:00","criticalityDate":"1974-09-12T00:00:00","gridDate":"1974-11-11T00:00:00","commercialDate":"1975-12-31T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Southern Nuclear Operating Company, Inc.","ownerName":"GEORGIA POWER CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":820,"defaultImageName":"820.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":454985,"ageNet":454968.00,"lifetimeFactor":null},{"id":687,"countryCode":"US","unitName":"HATCH-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":358,"siteName":"HATCH","thermalPower":2804,"grossElectricalCapacity":921,"netElectricalCapacity":883,"designNetElectricalCapacity":784,"constructionDate":"1972-02-01T00:00:00","criticalityDate":"1978-07-04T00:00:00","gridDate":"1978-09-22T00:00:00","commercialDate":"1979-09-05T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Southern Nuclear Operating Company, Inc.","ownerName":"GEORGIA POWER CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":820,"defaultImageName":"820.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":421121,"ageNet":421104.00,"lifetimeFactor":null},{"id":680,"countryCode":"US","unitName":"HOPE CREEK-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":360,"siteName":"HOPE CREEK","thermalPower":3840,"grossElectricalCapacity":1240,"netElectricalCapacity":1172,"designNetElectricalCapacity":1067,"constructionDate":"1976-03-01T00:00:00","criticalityDate":"1986-06-28T00:00:00","gridDate":"1986-08-01T00:00:00","commercialDate":"1986-12-20T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"PSEG Nuclear, LLC","ownerName":"PSEG Power, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":352241,"ageNet":352224.00,"lifetimeFactor":null},{"id":599,"countryCode":"US","unitName":"HUMBOLDT BAY","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"Natural cir.","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":361,"siteName":"HUMBOLDT BAY","thermalPower":220,"grossElectricalCapacity":65,"netElectricalCapacity":63,"designNetElectricalCapacity":65,"constructionDate":"1960-11-01T00:00:00","criticalityDate":"1963-02-16T00:00:00","gridDate":"1963-04-18T00:00:00","commercialDate":"1963-08-01T00:00:00","shutdownDate":"1976-07-02T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Pacific Gas and Electric Company\r\n","ownerName":"Pacific Gas and Electric Company\r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":556385,"ageNet":115776.00,"lifetimeFactor":null},{"id":643,"countryCode":"US","unitName":"INDIAN POINT-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"PWR","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":362,"siteName":"INDIAN POINT","thermalPower":615,"grossElectricalCapacity":277,"netElectricalCapacity":257,"designNetElectricalCapacity":265,"constructionDate":"1956-05-01T00:00:00","criticalityDate":"1962-08-02T00:00:00","gridDate":"1962-09-16T00:00:00","commercialDate":"1962-10-01T00:00:00","shutdownDate":"1974-10-31T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"Entergy Nuclear Operations, Inc.","turbineSupplierCode":null,"turbineSupplierName":null,"reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":825,"defaultImageName":"825.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":561521,"ageNet":106272.00,"lifetimeFactor":null},{"id":611,"countryCode":"US","unitName":"INDIAN POINT-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":362,"siteName":"INDIAN POINT","thermalPower":3216,"grossElectricalCapacity":1067,"netElectricalCapacity":998,"designNetElectricalCapacity":873,"constructionDate":"1966-10-14T00:00:00","criticalityDate":"1973-05-22T00:00:00","gridDate":"1973-06-26T00:00:00","commercialDate":"1974-08-01T00:00:00","shutdownDate":"2020-04-30T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"Entergy Nuclear Operations, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":825,"defaultImageName":"825.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":467057,"ageNet":410640.00,"lifetimeFactor":null},{"id":635,"countryCode":"US","unitName":"INDIAN POINT-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":362,"siteName":"INDIAN POINT","thermalPower":3216,"grossElectricalCapacity":1085,"netElectricalCapacity":1030,"designNetElectricalCapacity":965,"constructionDate":"1968-10-30T00:00:00","criticalityDate":"1976-04-04T00:00:00","gridDate":"1976-04-25T00:00:00","commercialDate":"1976-08-28T00:00:00","shutdownDate":"2021-04-28T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":"2021-04-29T00:00:00","decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"Entergy Nuclear Operations, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":825,"defaultImageName":"825.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":442241,"ageNet":394536.00,"lifetimeFactor":null},{"id":647,"countryCode":"US","unitName":"KEWAUNEE","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"WH 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":364,"siteName":"KEWAUNEE","thermalPower":1772,"grossElectricalCapacity":595,"netElectricalCapacity":566,"designNetElectricalCapacity":535,"constructionDate":"1968-08-06T00:00:00","criticalityDate":"1974-03-07T00:00:00","gridDate":"1974-04-08T00:00:00","commercialDate":"1974-06-16T00:00:00","shutdownDate":"2013-05-07T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Dominion Energy","ownerName":"Dominion Energy","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":66,"defaultImageName":"66.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":460193,"ageNet":342576.00,"lifetimeFactor":null},{"id":710,"countryCode":"US","unitName":"LACROSSE","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":null,"alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":365,"siteName":"LACROSSE","thermalPower":165,"grossElectricalCapacity":55,"netElectricalCapacity":48,"designNetElectricalCapacity":50,"constructionDate":"1963-03-01T00:00:00","criticalityDate":"1967-07-11T00:00:00","gridDate":"1968-04-26T00:00:00","commercialDate":"1969-11-07T00:00:00","shutdownDate":"1987-04-30T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"DAIRYLAND POWER COOPERATIVE","ownerName":null,"turbineSupplierCode":null,"turbineSupplierName":null,"reactorSupplierCode":"AC","reactorSupplierName":"ALLIS CHALMERS","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":512345,"ageNet":166632.00,"lifetimeFactor":null},{"id":692,"countryCode":"US","unitName":"LASALLE-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-5 (Mark 2)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":366,"siteName":"LASALLE","thermalPower":3546,"grossElectricalCapacity":1207,"netElectricalCapacity":1137,"designNetElectricalCapacity":1078,"constructionDate":"1973-09-10T00:00:00","criticalityDate":"1982-06-21T00:00:00","gridDate":"1982-09-04T00:00:00","commercialDate":"1984-01-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":358,"defaultImageName":"358.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":386489,"ageNet":386472.00,"lifetimeFactor":null},{"id":693,"countryCode":"US","unitName":"LASALLE-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-5 (Mark 2)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":366,"siteName":"LASALLE","thermalPower":3546,"grossElectricalCapacity":1207,"netElectricalCapacity":1140,"designNetElectricalCapacity":1078,"constructionDate":"1973-09-10T00:00:00","criticalityDate":"1984-03-10T00:00:00","gridDate":"1984-04-20T00:00:00","commercialDate":"1984-10-19T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":358,"defaultImageName":"358.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":372233,"ageNet":372216.00,"lifetimeFactor":null},{"id":678,"countryCode":"US","unitName":"LIMERICK-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 2)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":368,"siteName":"LIMERICK","thermalPower":3515,"grossElectricalCapacity":1194,"netElectricalCapacity":1134,"designNetElectricalCapacity":1055,"constructionDate":"1974-06-19T00:00:00","criticalityDate":"1984-12-22T00:00:00","gridDate":"1985-04-13T00:00:00","commercialDate":"1986-02-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":806,"defaultImageName":"806.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":363641,"ageNet":363624.00,"lifetimeFactor":null},{"id":679,"countryCode":"US","unitName":"LIMERICK-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 2)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":368,"siteName":"LIMERICK","thermalPower":3515,"grossElectricalCapacity":1194,"netElectricalCapacity":1134,"designNetElectricalCapacity":1055,"constructionDate":"1974-06-19T00:00:00","criticalityDate":"1989-08-12T00:00:00","gridDate":"1989-09-01T00:00:00","commercialDate":"1990-01-08T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":362,"defaultImageName":"362.JPG","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":325193,"ageNet":325176.00,"lifetimeFactor":null},{"id":649,"countryCode":"US","unitName":"MAINE YANKEE","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":null,"alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":369,"siteName":"MAINE YANKEE","thermalPower":2630,"grossElectricalCapacity":900,"netElectricalCapacity":860,"designNetElectricalCapacity":825,"constructionDate":"1968-10-01T00:00:00","criticalityDate":"1972-10-23T00:00:00","gridDate":"1972-11-08T00:00:00","commercialDate":"1972-12-28T00:00:00","shutdownDate":"1997-08-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"MAINE YANKEE ATOMIC POWER CO.","ownerName":null,"turbineSupplierCode":null,"turbineSupplierName":null,"reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":91,"defaultImageName":"91.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":472577,"ageNet":216768.00,"lifetimeFactor":null},{"id":690,"countryCode":"US","unitName":"MCGUIRE-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECND)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":371,"siteName":"MCGUIRE","thermalPower":3411,"grossElectricalCapacity":1215,"netElectricalCapacity":1158,"designNetElectricalCapacity":1180,"constructionDate":"1971-04-01T00:00:00","criticalityDate":"1981-08-08T00:00:00","gridDate":"1981-09-12T00:00:00","commercialDate":"1981-12-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Duke Energy  Corp.","ownerName":"Duke Energy  Corp.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":829,"defaultImageName":"829.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":395057,"ageNet":395040.00,"lifetimeFactor":null},{"id":691,"countryCode":"US","unitName":"MCGUIRE-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECND)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":371,"siteName":"MCGUIRE","thermalPower":3411,"grossElectricalCapacity":1215,"netElectricalCapacity":1158,"designNetElectricalCapacity":1180,"constructionDate":"1971-04-01T00:00:00","criticalityDate":"1983-05-08T00:00:00","gridDate":"1983-05-23T00:00:00","commercialDate":"1984-03-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Duke Energy  Corp.","ownerName":"Duke Energy  Corp.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":380225,"ageNet":380208.00,"lifetimeFactor":null},{"id":610,"countryCode":"US","unitName":"MILLSTONE-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":null,"alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":373,"siteName":"MILLSTONE","thermalPower":2011,"grossElectricalCapacity":684,"netElectricalCapacity":641,"designNetElectricalCapacity":660,"constructionDate":"1966-05-01T00:00:00","criticalityDate":"1970-10-26T00:00:00","gridDate":"1970-11-29T00:00:00","commercialDate":"1971-03-01T00:00:00","shutdownDate":"1998-07-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Dominion Energy","ownerName":null,"turbineSupplierCode":null,"turbineSupplierName":null,"reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":489617,"ageNet":241824.00,"lifetimeFactor":null},{"id":671,"countryCode":"US","unitName":"MILLSTONE-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":373,"siteName":"MILLSTONE","thermalPower":2700,"grossElectricalCapacity":918,"netElectricalCapacity":869,"designNetElectricalCapacity":870,"constructionDate":"1969-11-01T00:00:00","criticalityDate":"1975-10-17T00:00:00","gridDate":"1975-11-09T00:00:00","commercialDate":"1975-12-26T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Dominion Energy","ownerName":"Dominion Resources, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":966,"defaultImageName":"966.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":446273,"ageNet":446256.00,"lifetimeFactor":null},{"id":717,"countryCode":"US","unitName":"MILLSTONE-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYSUB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":373,"siteName":"MILLSTONE","thermalPower":3650,"grossElectricalCapacity":1280,"netElectricalCapacity":1210,"designNetElectricalCapacity":1159,"constructionDate":"1974-08-09T00:00:00","criticalityDate":"1986-01-23T00:00:00","gridDate":"1986-02-12T00:00:00","commercialDate":"1986-04-23T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Dominion Energy","ownerName":"Dominion Resources, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":966,"defaultImageName":"966.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":356321,"ageNet":356304.00,"lifetimeFactor":null},{"id":620,"countryCode":"US","unitName":"MONTICELLO","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-3 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":375,"siteName":"MONTICELLO","thermalPower":2004,"grossElectricalCapacity":691,"netElectricalCapacity":628,"designNetElectricalCapacity":545,"constructionDate":"1967-06-19T00:00:00","criticalityDate":"1970-12-10T00:00:00","gridDate":"1971-03-05T00:00:00","commercialDate":"1971-06-30T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Northern States Power Co. (subsidiary of Xcel Energy)","ownerName":"Xcel Energy","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":831,"defaultImageName":"831.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":487313,"ageNet":487296.00,"lifetimeFactor":null},{"id":607,"countryCode":"US","unitName":"NINE MILE POINT-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-2 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":379,"siteName":"NINE MILE POINT","thermalPower":1850,"grossElectricalCapacity":642,"netElectricalCapacity":613,"designNetElectricalCapacity":620,"constructionDate":"1965-04-12T00:00:00","criticalityDate":"1969-09-05T00:00:00","gridDate":"1969-11-09T00:00:00","commercialDate":"1969-12-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Nuclear, Électricité de France","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":832,"defaultImageName":"832.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":498857,"ageNet":498840.00,"lifetimeFactor":null},{"id":711,"countryCode":"US","unitName":"NINE MILE POINT-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-5 (Mark 2)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":379,"siteName":"NINE MILE POINT","thermalPower":3988,"grossElectricalCapacity":1320,"netElectricalCapacity":1277,"designNetElectricalCapacity":1100,"constructionDate":"1975-08-01T00:00:00","criticalityDate":"1987-05-23T00:00:00","gridDate":"1987-08-08T00:00:00","commercialDate":"1988-03-11T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Nuclear, Électricité de France","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":832,"defaultImageName":"832.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":343313,"ageNet":343296.00,"lifetimeFactor":null},{"id":672,"countryCode":"US","unitName":"NORTH ANNA-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYSUB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":381,"siteName":"NORTH ANNA","thermalPower":2940,"grossElectricalCapacity":990,"netElectricalCapacity":948,"designNetElectricalCapacity":907,"constructionDate":"1971-02-19T00:00:00","criticalityDate":"1978-04-05T00:00:00","gridDate":"1978-04-17T00:00:00","commercialDate":"1978-06-06T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Dominion Energy","ownerName":"Virginia Electric Power Co.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":833,"defaultImageName":"833.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":424913,"ageNet":424896.00,"lifetimeFactor":null},{"id":673,"countryCode":"US","unitName":"NORTH ANNA-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYSUB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":381,"siteName":"NORTH ANNA","thermalPower":2940,"grossElectricalCapacity":1011,"netElectricalCapacity":944,"designNetElectricalCapacity":907,"constructionDate":"1971-02-19T00:00:00","criticalityDate":"1980-06-12T00:00:00","gridDate":"1980-08-25T00:00:00","commercialDate":"1980-12-14T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Dominion Energy","ownerName":"Virginia Electric Power Co.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":833,"defaultImageName":"833.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":404249,"ageNet":404232.00,"lifetimeFactor":null},{"id":624,"countryCode":"US","unitName":"OCONEE-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"B&W LLP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":382,"siteName":"OCONEE","thermalPower":2568,"grossElectricalCapacity":891,"netElectricalCapacity":847,"designNetElectricalCapacity":887,"constructionDate":"1967-11-06T00:00:00","criticalityDate":"1973-04-19T00:00:00","gridDate":"1973-05-06T00:00:00","commercialDate":"1973-07-15T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Duke Energy  Corp.","ownerName":"Duke Energy  Corp.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":71,"defaultImageName":"71.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":468281,"ageNet":468264.00,"lifetimeFactor":null},{"id":625,"countryCode":"US","unitName":"OCONEE-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"B&W LLP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":382,"siteName":"OCONEE","thermalPower":2568,"grossElectricalCapacity":891,"netElectricalCapacity":848,"designNetElectricalCapacity":887,"constructionDate":"1967-11-06T00:00:00","criticalityDate":"1973-11-11T00:00:00","gridDate":"1973-12-05T00:00:00","commercialDate":"1974-09-09T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Duke Energy  Corp.","ownerName":"Duke Energy  Corp.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":71,"defaultImageName":"71.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":463169,"ageNet":463152.00,"lifetimeFactor":null},{"id":636,"countryCode":"US","unitName":"OCONEE-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"B&W LLP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":382,"siteName":"OCONEE","thermalPower":2568,"grossElectricalCapacity":900,"netElectricalCapacity":859,"designNetElectricalCapacity":887,"constructionDate":"1967-11-06T00:00:00","criticalityDate":"1974-09-05T00:00:00","gridDate":"1974-09-18T00:00:00","commercialDate":"1974-12-16T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Duke Energy  Corp.","ownerName":"Duke Energy  Corp.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":71,"defaultImageName":"71.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":456281,"ageNet":456264.00,"lifetimeFactor":null},{"id":606,"countryCode":"US","unitName":"OYSTER CREEK","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"BWR-2 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":384,"siteName":"OYSTER CREEK","thermalPower":1930,"grossElectricalCapacity":652,"netElectricalCapacity":619,"designNetElectricalCapacity":650,"constructionDate":"1964-12-15T00:00:00","criticalityDate":"1969-05-03T00:00:00","gridDate":"1969-09-23T00:00:00","commercialDate":"1969-12-01T00:00:00","shutdownDate":"2018-09-17T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":368,"defaultImageName":"368.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":499985,"ageNet":429384.00,"lifetimeFactor":null},{"id":616,"countryCode":"US","unitName":"PALISADES","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"CE 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":385,"siteName":"PALISADES","thermalPower":2565,"grossElectricalCapacity":850,"netElectricalCapacity":805,"designNetElectricalCapacity":805,"constructionDate":"1967-03-12T00:00:00","criticalityDate":"1971-05-22T00:00:00","gridDate":"1971-12-29T00:00:00","commercialDate":null,"shutdownDate":"2022-05-20T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"Entergy Nuclear Operations, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":480137,"ageNet":441720.00,"lifetimeFactor":null},{"id":789,"countryCode":"US","unitName":"PALO VERDE-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE80 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":386,"siteName":"PALO VERDE","thermalPower":3990,"grossElectricalCapacity":1414,"netElectricalCapacity":1311,"designNetElectricalCapacity":1221,"constructionDate":"1976-05-25T00:00:00","criticalityDate":"1985-05-25T00:00:00","gridDate":"1985-06-10T00:00:00","commercialDate":"1986-01-28T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"ARIZONA PUBLIC SERVICE CO.","ownerName":"ARIZONA PUBLIC SERVICE CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":362249,"ageNet":362232.00,"lifetimeFactor":null},{"id":790,"countryCode":"US","unitName":"PALO VERDE-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE80 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":386,"siteName":"PALO VERDE","thermalPower":3990,"grossElectricalCapacity":1414,"netElectricalCapacity":1314,"designNetElectricalCapacity":1304,"constructionDate":"1976-06-01T00:00:00","criticalityDate":"1986-04-18T00:00:00","gridDate":"1986-05-20T00:00:00","commercialDate":"1986-09-19T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"ARIZONA PUBLIC SERVICE CO.","ownerName":"ARIZONA PUBLIC SERVICE CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":353993,"ageNet":353976.00,"lifetimeFactor":null},{"id":791,"countryCode":"US","unitName":"PALO VERDE-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE80 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":386,"siteName":"PALO VERDE","thermalPower":3990,"grossElectricalCapacity":1414,"netElectricalCapacity":1312,"designNetElectricalCapacity":1304,"constructionDate":"1976-06-01T00:00:00","criticalityDate":"1987-10-25T00:00:00","gridDate":"1987-11-28T00:00:00","commercialDate":"1988-01-08T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"ARIZONA PUBLIC SERVICE CO.","ownerName":"ARIZONA PUBLIC SERVICE CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":340625,"ageNet":340608.00,"lifetimeFactor":null},{"id":598,"countryCode":"US","unitName":"PATHFINDER","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"Prototype","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":387,"siteName":"PATHFINDER","thermalPower":220,"grossElectricalCapacity":63,"netElectricalCapacity":59,"designNetElectricalCapacity":59,"constructionDate":"1959-01-01T00:00:00","criticalityDate":"1964-01-01T00:00:00","gridDate":"1966-07-25T00:00:00","commercialDate":"1966-08-01T00:00:00","shutdownDate":"1967-10-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"NUCLEAR MANAGEMENT CO.","ownerName":"Xcel Energy","turbineSupplierCode":"AC","turbineSupplierName":"ALLIS CHALMERS","reactorSupplierCode":"AC","reactorSupplierName":"ALLIS CHALMERS","defaultImageId":78,"defaultImageName":"78.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":527729,"ageNet":10392.00,"lifetimeFactor":null},{"id":603,"countryCode":"US","unitName":"PEACH BOTTOM-1","typeName":"High-Temperature Gas-Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":null,"alternateName":null,"typeCode":"HTGR","statusCode":"4S","siteId":388,"siteName":"PEACH BOTTOM","thermalPower":115,"grossElectricalCapacity":42,"netElectricalCapacity":40,"designNetElectricalCapacity":40,"constructionDate":"1962-02-01T00:00:00","criticalityDate":"1966-03-03T00:00:00","gridDate":"1967-01-27T00:00:00","commercialDate":"1967-06-01T00:00:00","shutdownDate":"1974-11-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Generation Co., LLC","turbineSupplierCode":null,"turbineSupplierName":null,"reactorSupplierCode":"GA","reactorSupplierName":"GENERAL ATOMIC CORP.","defaultImageId":706,"defaultImageName":"706.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":523265,"ageNet":68040.00,"lifetimeFactor":null},{"id":629,"countryCode":"US","unitName":"PEACH BOTTOM-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":388,"siteName":"PEACH BOTTOM","thermalPower":3951,"grossElectricalCapacity":1412,"netElectricalCapacity":1300,"designNetElectricalCapacity":1065,"constructionDate":"1968-01-31T00:00:00","criticalityDate":"1973-09-16T00:00:00","gridDate":"1974-02-18T00:00:00","commercialDate":"1974-07-05T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"EXELON Corp. (50%) \r\nPSEG Power (50%)","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":706,"defaultImageName":"706.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":461369,"ageNet":461352.00,"lifetimeFactor":null},{"id":630,"countryCode":"US","unitName":"PEACH BOTTOM-3","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":388,"siteName":"PEACH BOTTOM","thermalPower":3951,"grossElectricalCapacity":1412,"netElectricalCapacity":1331,"designNetElectricalCapacity":1065,"constructionDate":"1968-01-31T00:00:00","criticalityDate":"1974-08-07T00:00:00","gridDate":"1974-09-01T00:00:00","commercialDate":"1974-12-23T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"EXELON Corp. (50%) \r\nPSEG Power (50%)","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":706,"defaultImageName":"706.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":456689,"ageNet":456672.00,"lifetimeFactor":null},{"id":725,"countryCode":"US","unitName":"PERRY-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-6 (Mark 3)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":391,"siteName":"PERRY","thermalPower":3758,"grossElectricalCapacity":1303,"netElectricalCapacity":1240,"designNetElectricalCapacity":1205,"constructionDate":"1974-10-01T00:00:00","criticalityDate":"1986-06-06T00:00:00","gridDate":"1986-12-19T00:00:00","commercialDate":"1987-11-18T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"FIRST ENERGY NUCLEAR OPERATING CO.","ownerName":"CLEVELAND ELECTRIC ILLUMINATING CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":568,"defaultImageName":"568.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":348881,"ageNet":348864.00,"lifetimeFactor":null},{"id":639,"countryCode":"US","unitName":"PILGRIM-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"BWR-3 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":394,"siteName":"PILGRIM","thermalPower":2028,"grossElectricalCapacity":711,"netElectricalCapacity":677,"designNetElectricalCapacity":655,"constructionDate":"1968-08-26T00:00:00","criticalityDate":"1972-06-16T00:00:00","gridDate":"1972-07-19T00:00:00","commercialDate":"1972-12-01T00:00:00","shutdownDate":"2019-05-31T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"Entergy Nuclear Operations, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":475265,"ageNet":410808.00,"lifetimeFactor":null},{"id":894,"countryCode":"US","unitName":"PIQUA","typeName":"Organic Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"OCM (Organically Cooled and Moderated Reactor)","alternateName":null,"typeCode":"OMR","statusCode":"4S","siteId":395,"siteName":"PIQUA","thermalPower":46,"grossElectricalCapacity":12,"netElectricalCapacity":12,"designNetElectricalCapacity":11,"constructionDate":"1960-01-01T00:00:00","criticalityDate":"1961-01-01T00:00:00","gridDate":"1963-07-01T00:00:00","commercialDate":"1963-11-01T00:00:00","shutdownDate":"1966-01-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"City of Piqua Government","ownerName":"U.S. Atomic Energy Commission","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":554609,"ageNet":21960.00,"lifetimeFactor":null},{"id":622,"countryCode":"US","unitName":"POINT BEACH-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":396,"siteName":"POINT BEACH","thermalPower":1800,"grossElectricalCapacity":640,"netElectricalCapacity":591,"designNetElectricalCapacity":497,"constructionDate":"1967-07-19T00:00:00","criticalityDate":"1970-11-02T00:00:00","gridDate":"1970-11-06T00:00:00","commercialDate":"1970-12-21T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"NextEra Energy Resources, LLC\r\n","ownerName":"NextEra Energy Resources, LLC\r\n","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":839,"defaultImageName":"839.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":490169,"ageNet":490152.00,"lifetimeFactor":null},{"id":644,"countryCode":"US","unitName":"POINT BEACH-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":396,"siteName":"POINT BEACH","thermalPower":1800,"grossElectricalCapacity":640,"netElectricalCapacity":591,"designNetElectricalCapacity":497,"constructionDate":"1968-07-25T00:00:00","criticalityDate":"1972-05-30T00:00:00","gridDate":"1972-08-02T00:00:00","commercialDate":"1972-10-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"NextEra Energy Resources, LLC\r\n","ownerName":"NextEra Energy Resources, LLC\r\n","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":839,"defaultImageName":"839.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":474929,"ageNet":474912.00,"lifetimeFactor":null},{"id":633,"countryCode":"US","unitName":"PRAIRIE ISLAND-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":397,"siteName":"PRAIRIE ISLAND","thermalPower":1677,"grossElectricalCapacity":566,"netElectricalCapacity":522,"designNetElectricalCapacity":530,"constructionDate":"1968-06-25T00:00:00","criticalityDate":"1973-12-01T00:00:00","gridDate":"1973-12-04T00:00:00","commercialDate":"1973-12-16T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Northern States Power Co. (subsidiary of Xcel Energy)","ownerName":"Xcel Energy","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":918,"defaultImageName":"918.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":463193,"ageNet":463176.00,"lifetimeFactor":null},{"id":648,"countryCode":"US","unitName":"PRAIRIE ISLAND-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":397,"siteName":"PRAIRIE ISLAND","thermalPower":1677,"grossElectricalCapacity":560,"netElectricalCapacity":519,"designNetElectricalCapacity":530,"constructionDate":"1969-06-25T00:00:00","criticalityDate":"1974-12-17T00:00:00","gridDate":"1974-12-21T00:00:00","commercialDate":"1974-12-21T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Northern States Power Co. (subsidiary of Xcel Energy)","ownerName":"Xcel Energy","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":918,"defaultImageName":"918.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":454025,"ageNet":454008.00,"lifetimeFactor":null},{"id":615,"countryCode":"US","unitName":"QUAD CITIES-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-3 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":398,"siteName":"QUAD CITIES","thermalPower":2957,"grossElectricalCapacity":940,"netElectricalCapacity":908,"designNetElectricalCapacity":789,"constructionDate":"1967-02-15T00:00:00","criticalityDate":"1971-10-18T00:00:00","gridDate":"1972-04-12T00:00:00","commercialDate":"1973-02-18T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon (75%), MidAmerican Energy (25%)\r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":707,"defaultImageName":"707.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":477617,"ageNet":477600.00,"lifetimeFactor":null},{"id":621,"countryCode":"US","unitName":"QUAD CITIES-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-3 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":398,"siteName":"QUAD CITIES","thermalPower":2957,"grossElectricalCapacity":940,"netElectricalCapacity":911,"designNetElectricalCapacity":789,"constructionDate":"1967-02-15T00:00:00","criticalityDate":"1972-04-26T00:00:00","gridDate":"1972-05-23T00:00:00","commercialDate":"1973-03-10T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon (75%), MidAmerican Energy (25%)\r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":707,"defaultImageName":"707.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":476633,"ageNet":476616.00,"lifetimeFactor":null},{"id":651,"countryCode":"US","unitName":"RANCHO SECO-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"PWR","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":400,"siteName":"RANCHO SECO","thermalPower":2772,"grossElectricalCapacity":917,"netElectricalCapacity":873,"designNetElectricalCapacity":918,"constructionDate":"1969-04-01T00:00:00","criticalityDate":"1974-09-16T00:00:00","gridDate":"1974-10-13T00:00:00","commercialDate":"1975-04-17T00:00:00","shutdownDate":"1989-06-07T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"SACRAMENTO MUNICIPAL UTILITY DISTRICT","ownerName":"Sacramento Municipal Utility District ","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":455681,"ageNet":128424.00,"lifetimeFactor":null},{"id":739,"countryCode":"US","unitName":"RIVER BEND-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-6 (Mark 3)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":401,"siteName":"RIVER BEND","thermalPower":3091,"grossElectricalCapacity":1016,"netElectricalCapacity":967,"designNetElectricalCapacity":966,"constructionDate":"1977-03-25T00:00:00","criticalityDate":"1985-10-31T00:00:00","gridDate":"1985-12-03T00:00:00","commercialDate":"1986-06-16T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"ENTERGY GULF STATES, INC.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":722,"defaultImageName":"722.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":358025,"ageNet":358008.00,"lifetimeFactor":null},{"id":619,"countryCode":"US","unitName":"ROBINSON-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYAMB)","alternateName":"H. B. Robinson 2","typeCode":"PWR","statusCode":"1O","siteId":355,"siteName":"H.B. ROBINSON","thermalPower":2339,"grossElectricalCapacity":780,"netElectricalCapacity":741,"designNetElectricalCapacity":700,"constructionDate":"1967-04-13T00:00:00","criticalityDate":"1970-09-20T00:00:00","gridDate":"1970-09-26T00:00:00","commercialDate":"1971-03-07T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Progress Energy","ownerName":"PROGRESS ENERGY Carolinas, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":823,"defaultImageName":"823.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":491153,"ageNet":491136.00,"lifetimeFactor":null},{"id":627,"countryCode":"US","unitName":"SALEM-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":402,"siteName":"SALEM","thermalPower":3459,"grossElectricalCapacity":1254,"netElectricalCapacity":1169,"designNetElectricalCapacity":1090,"constructionDate":"1968-09-25T00:00:00","criticalityDate":"1976-12-11T00:00:00","gridDate":"1976-12-25T00:00:00","commercialDate":"1977-06-30T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"PSEG Nuclear, LLC","ownerName":"PSEG Power, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":545,"defaultImageName":"545.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":436385,"ageNet":436368.00,"lifetimeFactor":null},{"id":650,"countryCode":"US","unitName":"SALEM-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":402,"siteName":"SALEM","thermalPower":3459,"grossElectricalCapacity":1200,"netElectricalCapacity":1158,"designNetElectricalCapacity":1115,"constructionDate":"1968-09-25T00:00:00","criticalityDate":"1980-08-08T00:00:00","gridDate":"1981-06-03T00:00:00","commercialDate":"1981-10-13T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"PSEG Nuclear, LLC","ownerName":"PSEG Power, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":545,"defaultImageName":"545.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":397481,"ageNet":397464.00,"lifetimeFactor":null},{"id":604,"countryCode":"US","unitName":"SAN ONOFRE-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"PWR","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":403,"siteName":"SAN ONOFRE","thermalPower":1347,"grossElectricalCapacity":456,"netElectricalCapacity":436,"designNetElectricalCapacity":436,"constructionDate":"1964-05-01T00:00:00","criticalityDate":"1967-06-14T00:00:00","gridDate":"1967-07-16T00:00:00","commercialDate":"1968-01-01T00:00:00","shutdownDate":"1992-11-30T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"SOUTHERN CALIFORNIA EDISON Co.","ownerName":"SOUTHERN CALIFORNIA EDISON Co.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":842,"defaultImageName":"842.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":519185,"ageNet":222456.00,"lifetimeFactor":null},{"id":683,"countryCode":"US","unitName":"SAN ONOFRE-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"CE (2-loop) DRYAMB","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":403,"siteName":"SAN ONOFRE","thermalPower":3438,"grossElectricalCapacity":1127,"netElectricalCapacity":1070,"designNetElectricalCapacity":1070,"constructionDate":"1974-03-01T00:00:00","criticalityDate":"1982-07-26T00:00:00","gridDate":"1982-09-20T00:00:00","commercialDate":"1983-08-08T00:00:00","shutdownDate":"2013-06-07T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"SOUTHERN CALIFORNIA EDISON Co.","ownerName":"SOUTHERN CALIFORNIA EDISON Co.","turbineSupplierCode":"GECTG","turbineSupplierName":"GEC TURBINE GENERATORS, LTD.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":842,"defaultImageName":"842.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":386105,"ageNet":269232.00,"lifetimeFactor":null},{"id":684,"countryCode":"US","unitName":"SAN ONOFRE-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"CE (2-loop) DRYAMB","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":403,"siteName":"SAN ONOFRE","thermalPower":3438,"grossElectricalCapacity":1127,"netElectricalCapacity":1080,"designNetElectricalCapacity":1070,"constructionDate":"1974-03-01T00:00:00","criticalityDate":"1983-08-29T00:00:00","gridDate":"1983-09-25T00:00:00","commercialDate":"1984-04-01T00:00:00","shutdownDate":"2013-06-07T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"SOUTHERN CALIFORNIA EDISON Co.","ownerName":"SOUTHERN CALIFORNIA EDISON Co.","turbineSupplierCode":"GECTG","turbineSupplierName":"GEC TURBINE GENERATORS, LTD.","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":842,"defaultImageName":"842.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":377225,"ageNet":260352.00,"lifetimeFactor":null},{"id":892,"countryCode":"US","unitName":"SAXTON","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"25","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":404,"siteName":"SAXTON","thermalPower":24,"grossElectricalCapacity":3,"netElectricalCapacity":3,"designNetElectricalCapacity":3,"constructionDate":"1960-01-01T00:00:00","criticalityDate":"1967-01-01T00:00:00","gridDate":"1967-03-01T00:00:00","commercialDate":null,"shutdownDate":"1972-05-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Saxton Nuclear Experimental Reactor Corporation","ownerName":"Saxton Nuclear Experimanetal Corp.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":522473,"ageNet":45312.00,"lifetimeFactor":null},{"id":727,"countryCode":"US","unitName":"SEABROOK-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":405,"siteName":"SEABROOK","thermalPower":3648,"grossElectricalCapacity":1296,"netElectricalCapacity":1246,"designNetElectricalCapacity":1149,"constructionDate":"1976-07-07T00:00:00","criticalityDate":"1989-06-13T00:00:00","gridDate":"1990-05-29T00:00:00","commercialDate":"1990-08-19T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"NextEra Energy Resources, LLC\r\n","ownerName":"NextEra Energy Resources, LLC\r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":843,"defaultImageName":"843.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":318713,"ageNet":318696.00,"lifetimeFactor":null},{"id":663,"countryCode":"US","unitName":"SEQUOYAH-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECND)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":406,"siteName":"SEQUOYAH","thermalPower":3455,"grossElectricalCapacity":1221,"netElectricalCapacity":1152,"designNetElectricalCapacity":1148,"constructionDate":"1970-05-27T00:00:00","criticalityDate":"1980-07-05T00:00:00","gridDate":"1980-07-22T00:00:00","commercialDate":"1981-07-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Tennessee Valley Authority","ownerName":"Tennessee Valley Authority","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":547,"defaultImageName":"547.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":405065,"ageNet":405048.00,"lifetimeFactor":null},{"id":664,"countryCode":"US","unitName":"SEQUOYAH-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECND)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":406,"siteName":"SEQUOYAH","thermalPower":3455,"grossElectricalCapacity":1200,"netElectricalCapacity":1139,"designNetElectricalCapacity":1148,"constructionDate":"1970-05-27T00:00:00","criticalityDate":"1981-11-05T00:00:00","gridDate":"1981-12-23T00:00:00","commercialDate":"1982-06-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Tennessee Valley Authority","ownerName":"Tennessee Valley Authority","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":547,"defaultImageName":"547.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":392609,"ageNet":392592.00,"lifetimeFactor":null},{"id":890,"countryCode":"US","unitName":"SHIPPINGPORT","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"PLWBR","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":408,"siteName":"SHIPPINGPORT","thermalPower":236,"grossElectricalCapacity":68,"netElectricalCapacity":60,"designNetElectricalCapacity":60,"constructionDate":"1954-01-01T00:00:00","criticalityDate":"1957-01-01T00:00:00","gridDate":"1957-12-02T00:00:00","commercialDate":"1958-05-26T00:00:00","shutdownDate":"1982-10-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Department of Energy and Duquesne Light Co.","ownerName":"Department of Energy and Duquesne Light Co.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":603497,"ageNet":217656.00,"lifetimeFactor":null},{"id":659,"countryCode":"US","unitName":"SHOREHAM","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"BWR","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":409,"siteName":"SHOREHAM","thermalPower":2436,"grossElectricalCapacity":849,"netElectricalCapacity":820,"designNetElectricalCapacity":809,"constructionDate":"1972-11-01T00:00:00","criticalityDate":"1985-02-15T00:00:00","gridDate":"1986-08-01T00:00:00","commercialDate":null,"shutdownDate":"1989-06-28T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Long Island Power Authority","ownerName":"Long Island Lighting Company","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":352241,"ageNet":25488.00,"lifetimeFactor":null},{"id":764,"countryCode":"US","unitName":"SOUTH TEXAS-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":414,"siteName":"SOUTH TEXAS","thermalPower":3853,"grossElectricalCapacity":1354,"netElectricalCapacity":1280,"designNetElectricalCapacity":1250,"constructionDate":"1975-12-22T00:00:00","criticalityDate":"1988-03-08T00:00:00","gridDate":"1988-03-30T00:00:00","commercialDate":"1988-08-25T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"STP Nuclear Operating Co.","ownerName":"NRG Energy, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":76,"defaultImageName":"76.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":337673,"ageNet":337656.00,"lifetimeFactor":null},{"id":765,"countryCode":"US","unitName":"SOUTH TEXAS-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":414,"siteName":"SOUTH TEXAS","thermalPower":3853,"grossElectricalCapacity":1354,"netElectricalCapacity":1280,"designNetElectricalCapacity":1250,"constructionDate":"1975-12-22T00:00:00","criticalityDate":"1989-03-12T00:00:00","gridDate":"1989-04-11T00:00:00","commercialDate":"1989-06-19T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"STP Nuclear Operating Co.","ownerName":"NRG Energy, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":76,"defaultImageName":"76.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":328625,"ageNet":328608.00,"lifetimeFactor":null},{"id":670,"countryCode":"US","unitName":"ST. LUCIE-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":415,"siteName":"ST. LUCIE","thermalPower":3020,"grossElectricalCapacity":1045,"netElectricalCapacity":981,"designNetElectricalCapacity":830,"constructionDate":"1970-07-01T00:00:00","criticalityDate":"1976-04-22T00:00:00","gridDate":"1976-05-07T00:00:00","commercialDate":"1976-12-21T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Florida Power & Light Co.","ownerName":"Florida Power & Light Co.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":441953,"ageNet":441936.00,"lifetimeFactor":null},{"id":698,"countryCode":"US","unitName":"ST. LUCIE-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":415,"siteName":"ST. LUCIE","thermalPower":3020,"grossElectricalCapacity":1050,"netElectricalCapacity":987,"designNetElectricalCapacity":830,"constructionDate":"1977-06-02T00:00:00","criticalityDate":"1983-06-02T00:00:00","gridDate":"1983-06-13T00:00:00","commercialDate":"1983-08-08T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Florida Power & Light Co.","ownerName":"Florida Power & Light Co.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":379721,"ageNet":379704.00,"lifetimeFactor":null},{"id":701,"countryCode":"US","unitName":"SUMMER-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYAMB)","alternateName":"Virgil C. Summer 1","typeCode":"PWR","statusCode":"1O","siteId":429,"siteName":"VIRGIL C. SUMMER","thermalPower":2900,"grossElectricalCapacity":1006,"netElectricalCapacity":973,"designNetElectricalCapacity":900,"constructionDate":"1973-03-21T00:00:00","criticalityDate":"1982-10-22T00:00:00","gridDate":"1982-11-16T00:00:00","commercialDate":"1984-01-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"SOUTH CAROLINA ELECTRIC & GAS CO.","ownerName":"SOUTH CAROLINA ELECTRIC & GAS CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":847,"defaultImageName":"847.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":384737,"ageNet":384720.00,"lifetimeFactor":null},{"id":631,"countryCode":"US","unitName":"SURRY-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYSUB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":419,"siteName":"SURRY","thermalPower":2587,"grossElectricalCapacity":890,"netElectricalCapacity":838,"designNetElectricalCapacity":788,"constructionDate":"1968-06-25T00:00:00","criticalityDate":"1972-07-01T00:00:00","gridDate":"1972-07-04T00:00:00","commercialDate":"1972-12-22T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Dominion Energy","ownerName":"Dominion Resources, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":319,"defaultImageName":"319.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":475625,"ageNet":475608.00,"lifetimeFactor":null},{"id":632,"countryCode":"US","unitName":"SURRY-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYSUB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":419,"siteName":"SURRY","thermalPower":2587,"grossElectricalCapacity":890,"netElectricalCapacity":838,"designNetElectricalCapacity":788,"constructionDate":"1968-06-25T00:00:00","criticalityDate":"1973-03-07T00:00:00","gridDate":"1973-03-10T00:00:00","commercialDate":"1973-05-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Dominion Energy","ownerName":"Dominion Resources, Inc.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":319,"defaultImageName":"319.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":469649,"ageNet":469632.00,"lifetimeFactor":null},{"id":696,"countryCode":"US","unitName":"SUSQUEHANNA-1","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 2)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":420,"siteName":"SUSQUEHANNA","thermalPower":3952,"grossElectricalCapacity":1330,"netElectricalCapacity":1257,"designNetElectricalCapacity":1065,"constructionDate":"1973-11-02T00:00:00","criticalityDate":"1982-09-10T00:00:00","gridDate":"1982-11-16T00:00:00","commercialDate":"1983-06-08T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"PPL Susquehanna, LLC","ownerName":"PPL Corporation (former PENNSYLVANIA POWER & LIGHT CO. (PP&L))","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":384737,"ageNet":384720.00,"lifetimeFactor":null},{"id":697,"countryCode":"US","unitName":"SUSQUEHANNA-2","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Operational","countryName":"United States of America","model":"BWR-4 (Mark 2)","alternateName":null,"typeCode":"BWR","statusCode":"1O","siteId":420,"siteName":"SUSQUEHANNA","thermalPower":3952,"grossElectricalCapacity":1330,"netElectricalCapacity":1257,"designNetElectricalCapacity":1065,"constructionDate":"1973-11-02T00:00:00","criticalityDate":"1984-05-08T00:00:00","gridDate":"1984-07-03T00:00:00","commercialDate":"1985-02-12T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"PPL Susquehanna, LLC","ownerName":"PPL Corporation (former PENNSYLVANIA POWER & LIGHT CO. (PP&L))","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":370457,"ageNet":370440.00,"lifetimeFactor":null},{"id":637,"countryCode":"US","unitName":"THREE MILE ISLAND-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"B&W LLP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":421,"siteName":"THREE MILE ISLAND","thermalPower":2568,"grossElectricalCapacity":880,"netElectricalCapacity":819,"designNetElectricalCapacity":819,"constructionDate":"1968-05-18T00:00:00","criticalityDate":"1974-06-05T00:00:00","gridDate":"1974-06-19T00:00:00","commercialDate":"1974-09-02T00:00:00","shutdownDate":"2019-09-20T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Corporation \r\n","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":377,"defaultImageName":"377.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":458465,"ageNet":396696.00,"lifetimeFactor":null},{"id":657,"countryCode":"US","unitName":"THREE MILE ISLAND-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"PWR","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":421,"siteName":"THREE MILE ISLAND","thermalPower":2772,"grossElectricalCapacity":959,"netElectricalCapacity":880,"designNetElectricalCapacity":906,"constructionDate":"1969-11-01T00:00:00","criticalityDate":"1978-03-27T00:00:00","gridDate":"1978-04-21T00:00:00","commercialDate":"1978-12-30T00:00:00","shutdownDate":"1979-03-28T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"GENERAL PUBLIC UTILITIES\r\n(owned by FirstEnergy Corp.)","ownerName":null,"turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"B&W","reactorSupplierName":"BABCOCK & WILCOX CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":424817,"ageNet":8184.00,"lifetimeFactor":null},{"id":675,"countryCode":"US","unitName":"TROJAN","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":null,"alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":422,"siteName":"TROJAN","thermalPower":3411,"grossElectricalCapacity":1155,"netElectricalCapacity":1095,"designNetElectricalCapacity":1130,"constructionDate":"1970-02-01T00:00:00","criticalityDate":"1975-12-15T00:00:00","gridDate":"1975-12-23T00:00:00","commercialDate":"1976-05-20T00:00:00","shutdownDate":"1992-11-09T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"PORTLAND GENERAL ELECTRIC CO.","ownerName":null,"turbineSupplierCode":null,"turbineSupplierName":null,"reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":445217,"ageNet":147984.00,"lifetimeFactor":null},{"id":613,"countryCode":"US","unitName":"TURKEY POINT-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":423,"siteName":"TURKEY POINT","thermalPower":2644,"grossElectricalCapacity":829,"netElectricalCapacity":837,"designNetElectricalCapacity":693,"constructionDate":"1967-04-27T00:00:00","criticalityDate":"1972-10-20T00:00:00","gridDate":"1972-11-02T00:00:00","commercialDate":"1972-12-14T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Florida Power & Light Co.","ownerName":"Florida Power & Light Co.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":848,"defaultImageName":"848.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":472721,"ageNet":472704.00,"lifetimeFactor":null},{"id":614,"countryCode":"US","unitName":"TURKEY POINT-4","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 3LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":423,"siteName":"TURKEY POINT","thermalPower":2644,"grossElectricalCapacity":829,"netElectricalCapacity":821,"designNetElectricalCapacity":693,"constructionDate":"1967-04-27T00:00:00","criticalityDate":"1973-06-11T00:00:00","gridDate":"1973-06-21T00:00:00","commercialDate":"1973-09-07T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Florida Power & Light Co.","ownerName":"Florida Power & Light Co.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":848,"defaultImageName":"848.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":467177,"ageNet":467160.00,"lifetimeFactor":null},{"id":626,"countryCode":"US","unitName":"VERMONT YANKEE","typeName":"Boiling Light-Water-Cooled and Moderated Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"BWR-4 (Mark 1)","alternateName":null,"typeCode":"BWR","statusCode":"4S","siteId":427,"siteName":"VERMONT YANKEE","thermalPower":1912,"grossElectricalCapacity":635,"netElectricalCapacity":605,"designNetElectricalCapacity":514,"constructionDate":"1967-12-11T00:00:00","criticalityDate":"1972-03-24T00:00:00","gridDate":"1972-09-20T00:00:00","commercialDate":"1972-11-30T00:00:00","shutdownDate":"2014-12-29T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"Entergy Nuclear Operations, Inc.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"GE","reactorSupplierName":"GENERAL ELECTRIC CO.","defaultImageId":789,"defaultImageName":"789.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":473753,"ageNet":370560.00,"lifetimeFactor":null},{"id":718,"countryCode":"US","unitName":"VOGTLE-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":430,"siteName":"VOGTLE","thermalPower":3626,"grossElectricalCapacity":1229,"netElectricalCapacity":1150,"designNetElectricalCapacity":1122,"constructionDate":"1976-08-01T00:00:00","criticalityDate":"1987-03-09T00:00:00","gridDate":"1987-03-27T00:00:00","commercialDate":"1987-06-01T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Southern Nuclear Operating Company, Inc.","ownerName":"GEORGIA POWER CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":849,"defaultImageName":"849.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":346529,"ageNet":346512.00,"lifetimeFactor":null},{"id":719,"countryCode":"US","unitName":"VOGTLE-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":430,"siteName":"VOGTLE","thermalPower":3626,"grossElectricalCapacity":1229,"netElectricalCapacity":1152,"designNetElectricalCapacity":1101,"constructionDate":"1976-08-01T00:00:00","criticalityDate":"1989-03-28T00:00:00","gridDate":"1989-04-10T00:00:00","commercialDate":"1989-05-20T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Southern Nuclear Operating Company, Inc.","ownerName":"GEORGIA POWER CO.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":849,"defaultImageName":"849.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":328649,"ageNet":328632.00,"lifetimeFactor":null},{"id":1042,"countryCode":"US","unitName":"VOGTLE-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"AP-1000","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":430,"siteName":"VOGTLE","thermalPower":3400,"grossElectricalCapacity":1250,"netElectricalCapacity":1117,"designNetElectricalCapacity":1117,"constructionDate":"2013-03-02T00:00:00","criticalityDate":"2023-03-01T00:00:00","gridDate":"2023-03-31T00:00:00","commercialDate":"2023-07-31T00:00:00","shutdownDate":null,"constructionLicenseDate":"2008-03-18T00:00:00","decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Southern Nuclear Operating Company, Inc.","ownerName":"GEORGIA POWER CO.","turbineSupplierCode":"TOSHIBA","turbineSupplierName":"TOSHIBA CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":30857,"ageNet":30840.00,"lifetimeFactor":null},{"id":1043,"countryCode":"US","unitName":"VOGTLE-4","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"AP-1000","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":430,"siteName":"VOGTLE","thermalPower":3400,"grossElectricalCapacity":1250,"netElectricalCapacity":1117,"designNetElectricalCapacity":1117,"constructionDate":"2013-11-19T00:00:00","criticalityDate":"2024-02-14T00:00:00","gridDate":"2024-03-06T00:00:00","commercialDate":"2024-04-29T00:00:00","shutdownDate":null,"constructionLicenseDate":"2008-03-28T00:00:00","decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Southern Nuclear Operating Company, Inc.","ownerName":"GEORGIA POWER CO.","turbineSupplierCode":"TOSHIBA","turbineSupplierName":"TOSHIBA CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":22673,"ageNet":22656.00,"lifetimeFactor":null},{"id":695,"countryCode":"US","unitName":"WATERFORD-3","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"CE 2LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":431,"siteName":"WATERFORD","thermalPower":3716,"grossElectricalCapacity":1250,"netElectricalCapacity":1168,"designNetElectricalCapacity":1104,"constructionDate":"1974-11-14T00:00:00","criticalityDate":"1985-03-04T00:00:00","gridDate":"1985-03-18T00:00:00","commercialDate":"1985-09-24T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Entergy Nuclear Operations, Inc.","ownerName":"ENTERGY LOUISIANA, INC.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"CE","reactorSupplierName":"COMBUSTION ENGINEERING CO.","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":364265,"ageNet":364248.00,"lifetimeFactor":null},{"id":699,"countryCode":"US","unitName":"WATTS BAR-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECND)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":432,"siteName":"WATTS BAR","thermalPower":3459,"grossElectricalCapacity":1210,"netElectricalCapacity":1157,"designNetElectricalCapacity":1218,"constructionDate":"1973-07-20T00:00:00","criticalityDate":"1996-01-01T00:00:00","gridDate":"1996-02-06T00:00:00","commercialDate":"1996-05-27T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Tennessee Valley Authority","ownerName":"Tennessee Valley Authority","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":329,"defaultImageName":"329.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":268817,"ageNet":268800.00,"lifetimeFactor":null},{"id":700,"countryCode":"US","unitName":"WATTS BAR-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (ICECND)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":432,"siteName":"WATTS BAR","thermalPower":3411,"grossElectricalCapacity":1218,"netElectricalCapacity":1164,"designNetElectricalCapacity":1165,"constructionDate":"1973-09-01T00:00:00","criticalityDate":"2016-05-23T00:00:00","gridDate":"2016-06-03T00:00:00","commercialDate":"2016-10-19T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":"1985-09-17T00:00:00","rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Tennessee Valley Authority","ownerName":"Tennessee Valley Authority","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":329,"defaultImageName":"329.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":"2007-10-15T00:00:00","latestRestartOperationsDate":null,"ageGross":90665,"ageNet":90648.00,"lifetimeFactor":null},{"id":751,"countryCode":"US","unitName":"WOLF CREEK","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Operational","countryName":"United States of America","model":"WH 4LP (DRYAMB)","alternateName":null,"typeCode":"PWR","statusCode":"1O","siteId":434,"siteName":"WOLF CREEK","thermalPower":3565,"grossElectricalCapacity":1285,"netElectricalCapacity":1200,"designNetElectricalCapacity":1170,"constructionDate":"1977-05-31T00:00:00","criticalityDate":"1985-05-22T00:00:00","gridDate":"1985-06-12T00:00:00","commercialDate":"1985-09-03T00:00:00","shutdownDate":null,"constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"WOLF CREEK NUCLEAR OPERATING CORP.","ownerName":"Kansas City Power & Light Co.","turbineSupplierCode":"GE","turbineSupplierName":"GENERAL ELECTRIC CO.","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":851,"defaultImageName":"851.jpg","informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":362201,"ageNet":362184.00,"lifetimeFactor":null},{"id":638,"countryCode":"US","unitName":"YANKEE NPS","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"PWR","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":435,"siteName":"YANKEE NPS","thermalPower":600,"grossElectricalCapacity":180,"netElectricalCapacity":167,"designNetElectricalCapacity":175,"constructionDate":"1957-11-01T00:00:00","criticalityDate":"1960-08-19T00:00:00","gridDate":"1960-11-10T00:00:00","commercialDate":"1961-07-01T00:00:00","shutdownDate":"1991-10-01T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"YANKEE ATOMIC ELECTRIC CO.","ownerName":"YANKEE ATOMIC ELECTRIC CO.","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":577721,"ageNet":270768.00,"lifetimeFactor":null},{"id":640,"countryCode":"US","unitName":"ZION-1","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"WH 4LP","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":438,"siteName":"ZION","thermalPower":3250,"grossElectricalCapacity":1085,"netElectricalCapacity":1040,"designNetElectricalCapacity":1040,"constructionDate":"1968-12-01T00:00:00","criticalityDate":"1973-06-19T00:00:00","gridDate":"1973-06-28T00:00:00","commercialDate":"1973-12-31T00:00:00","shutdownDate":"1998-02-13T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Generation Co., LLC","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":467009,"ageNet":215904.00,"lifetimeFactor":null},{"id":646,"countryCode":"US","unitName":"ZION-2","typeName":"Pressurized Light-Water-Moderated and Cooled Reactor","statusName":"Permanent Shutdown","countryName":"United States of America","model":"WH 4LP","alternateName":null,"typeCode":"PWR","statusCode":"4S","siteId":438,"siteName":"ZION","thermalPower":3250,"grossElectricalCapacity":1085,"netElectricalCapacity":1040,"designNetElectricalCapacity":1040,"constructionDate":"1968-12-01T00:00:00","criticalityDate":"1973-12-24T00:00:00","gridDate":"1973-12-26T00:00:00","commercialDate":"1974-09-17T00:00:00","shutdownDate":"1998-02-13T00:00:00","constructionLicenseDate":null,"decommissioningStartDate":null,"decommissioningEndDate":null,"latestOperatingLicenseDate":null,"latestSuspendedOperationsDate":null,"latestSuspendedConstructionsDate":null,"rupUnitTypeCode":"Net","rupUnitTypeName":"Net","regionName":"North America","operatorName":"Exelon Generation Co., LLC","ownerName":"Exelon Generation Co., LLC","turbineSupplierCode":"WH","turbineSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","reactorSupplierCode":"WH","reactorSupplierName":"WESTINGHOUSE ELECTRIC CORPORATION","defaultImageId":null,"defaultImageName":null,"informationStatusCode":"PUB","informationStatusDescription":"Published","latestRestartConstructionsDate":null,"latestRestartOperationsDate":null,"ageGross":462665,"ageNet":211560.00,"lifetimeFactor":null}]}